600A T Deadbreak Connector
  • Product Details

  • Product Tags

Anhuang specialized in Deadbreak Connector ,we supply high quality Dead break Connector.

Implementation of standards:

● Separable insulated connector system for distribution systems above; ANSI / IEEE Std386-2006600V

● Exposed semiconductor jackets for high – voltage cable splices and separable insulated connectors;

● Extruded insulated power cables and their accessories with rated voltages above 1 kV (Um = 1.2 kV) to 30 kV (Um – 35 kV);

● Test methods for accessories for power cables with rated voltages from 6 kV (Um =7.2 kV) to 30 kV (Um = 35 kV);

●Extruded insulated power cables and their accessories with rated voltages from 1 kV(Um = 1.2 kV) to 35 kV (Um = 40.5 kV).

● Insulation coordination of high – voltage transmission and distribution equipment GB/T4109-1999

● Technical condition of high – voltage bushing;

● Gap-free metal – oxide surge arresters;

● Power cables with extension cones – Partition sets dimensions of sleeves and separable fittings for Um below 35 kV DIN 47636-7-1990.

15kV/24kV 600A Class T Deadbreak Connector is used to terminate high voltage underground cable to transformers, switches, switchgear and other apparatus. It is fully shielded, submersible. Our Systems offers an exclusive optional capacitive test point similar to test points on 200A elbow connectors. This allows use of Fault Indicators. T connectors include the T Cable Connector and the load break bushing extender. They also provides a convenient location for a M.O.V.E. arrester or grounding elbow. They available conductor cross section is 25-500m² for 24kV cable.

 

Continuous voltage ratings

Item

15kV data

25kV data

35kV data

Continuous operating voltage

8.7kV/14.4kV

15.2kV 26.3kV

26kV/35kV

AC withstand voltage

45kV/1min

55kV/5min

117kV/5min

DC withstand voltage

53kV/15min

78kV/15m in

104kV

1.5/50 μs  Im pulse with stand voltage

95kV

125kV

215kV

Partial discharge voltage

13kV

22kV

45kV

 

Current rating

Item

200AMP

600AMP

Load operating

current

Available in 14.4kV and 200A 10 times under

breaking and closed operation

 

Fault closed

current

Available in 14.4kV, 1000N0.175 1 time under

by fault closed operation

 

Heat stable

current

16kA 1s

30kA 2s

Peak withstand

current

10kA

105kA

 img2222

Reference No. Conductor cross section(mm²) Stretch range over insulation(mm)
AH TT 24/600-35

35

18.6

AH TT 24/600-50

50

19.6

AH TT 24/600-70

70

21

AH TT 24/600-95

95

22.6

AH TT 24/600-120

120

24.2

AH TT 24/600-150

150

25.6

AH TT 24/600-185

185

27.2

AH TT 24/600-240

240

28.7

AH TT 24/600-300

300

31.1

AH TT 24/600-400

400

33.2

Inquiry

If you have any enquiry about quotation or cooperation,please feel free to email us at global@anhelec.com or use the following enquiry form. Our sales will contact you within 24 hours. Thank you for your interest in our products.