Anhuang specialized in Straight connector ,we supply high quality Straight connector.
●Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.
● Built-in capacitive test point to determine the circuit status or install a fault indicator.
● No minimum phase clearance requirements.
●Mounting can be vertical, horizontal, or any angle in between.
• For connection of polymeric cable to transformers, switchgear, motors and other equipment with a pre-moulded separable connector.
●For indoor and outdoor installations.
● System voltage up to 24 kV.
● Continuous current 250 A (300 A overload for 8 hours).
● Cable particulars:
- Polymeric cable (XLPE, EPR, etc.)
-Copper or aluminum conductors
- Semiconducting or metallic screens
-Conductor size 25~120 mm2Kit contents:
Straight connector
Copper or Aluminum conductor cable lug
Steel installation tool
Clearing paper
Silicone lubricant
Installation instruction sheet
Quality certificate
1、Conducting Rod: pin type crimp connector can be copper or bimatel.
2、SEMI-CONDUCTIVE INSERT: Molded EPDM conducting rubber shielded controls electrical stress.
3、Capacitive Test Point: Capacitive test point provides a means to check circuit status. A molded EPDM conducting rubber cap earths the test point when not in use.
4、Stress Relief: The configuration of the outer screen and insulation provide cable stress relief.
5、Cable Entrance: The sized opening provides an interference fit to maintain a watertight scale.
6、SEMI-CONDUCTIVE SHIELD: Molded EPDM conducting rubber mates with
the cable screen to maintain screen continuity and ensure that the assembly is at earth potential.
7、Grounding Eye: Molded into the external screen for connection of an earthing wire.
8、Insulation: Molded EPDM insulating rubber is formulated and mixed in-house to ensure high quality.
9、Locking Ring Groove: Provision for an optional three-phase locking ring.
Description | Reference No. | Conductor crosssection (mm²) | Stretch range overinsulation (mm) |
25kV 250A Load break Straight Connector | AH ZTS-10/250-25 | 24 | 16.3-19.9 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-35 | 35 | 16.3-19.9 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-50 | 50 | 16.3-19.9 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-70 | 70 | 19.8-23.5 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-95 | 95 | 23.1-27.1 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-120 | 120 | 23.1-27 .1 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-35 | 35 | 23.1-27 .1 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-50 | 50 | 23.1-27.1 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-70 | 70 | 23.6-26.4 |
25kV 250A Load break Straight Connector | AH ZTS-10/250-95 | 95 | 23.6-26.4 |
25kV 250A Straight Connector | AH ZTS-10/250-120 | 120 | 27.9-33.5 |