Anhuang specialized in Loadbreak Elbow Connector, we supply high quality Loadbreak Elbow Connector.
l Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.
l Built-in capacitive test point to determine the circuit status or install a fault indicator.
l No minimum phase clearance requirements.
l Mounting can be vertical, horizontal, or any angle in between.
l For connection of polymeric cable to transformers, switchgear, motors and other equipment with a pre-molded separable connector.
l For indoor and outdoor installations.
l System voltage up to 24 kV.
l Continuous current 250 A (300 A overload for 8 hours).
l Cable particulars:
-Polymeric cable (XLPE, EPR, etc.)
- Copper or aluminum conductors
-Semiconducting or metallic screens
- Conductor size 25-120 mm²
Ratings Overview:
(Um) Maximum system voltage:25kV
Impulse withstand voltage:125kV
AC withstand voltage ,5min:54kV
Continuous operating current:250A
Overload (8 hrs. Max.) :300A
Short circuit withstand:12.5kA/1s
REMARK: All the data based on the standards IEC, Not the limited.Product Structure
1、Conducting Rod: Tin-plated copper pin screws into the conductor contact with the supplied hex key.
2、SEMI-CONDUCTIVE INSERT: Molded EPDM conducting rubber screen controls electrical stress.
3、Insulation: Molded EPDM insulating rubber is formulated and mixed in-house to ensure high quality.
4、Pulling Eye: Encapsulated stainless steel pulling eye with a decent to position the bail.
5、Capacitive Test Point: Capacitive test point provides means to check circuit status. Molded EPDM conducting rubber cap provides a watertight seal.
6、Stress Relief: The configuration of the outer shielded and the cable adapter provide cable stress relief.
7、Cable Adapter: The sized opening provides and interface fit to maintain a watertight seal.
8、Grounding Eye: Molded into the external screen for connection of an earth wire.
9、SEMI-CONDUCTIVE SHIELD: Molded EPDM conducting rubber mates with the cable screen to maintain screen continuity and ensure that the assembly is at earth potential.
10、Conductor Cable lug: Inertia welded bimetallic compression connector accepts copper or aluminum conductors.
Description | Reference No. | Conductor crosssection (mm²) | Stretch range overinsulation (mm) |
24kV 250A Load break Elbow Connector | AH ZT-10/250-25 | 24 | 16.3-19.9 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-35 | 35 | 16.3-19.9 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-50 | 50 | 16.3-19.9 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-70 | 70 | 19.8-23.5 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-95 | 95 | 23.1-27.1 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-120 | 120 | 23.1-27 .1 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-35 | 35 | 23.1-27 .1 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-50 | 50 | 23.1-27.1 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-70 | 70 | 23.6-26.4 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-95 | 95 | 23.6-26.4 |
24kV 250A Load break Elbow Connector | AH ZT-10/250-120 | 120 | 27.9-33.5 |